SEE – DIAGNOSE – TREAT

Optimal image quality means diagnostic safety as a basic precondition for successful treatment. Powerful image processing plays a leading role. All Infinix systems are equipped with innovative algorithms for excellent visualization of smallest vessels and interventional devices.

Please accept preferences-cookies to watch this video.

Next Generation Advanced Image Processing (AIP)
Next Generation Advanced Image Processing (AIP) produces more uniform images and the ability to visualize fine details. The software works in concert with hardware to optimize image display and minimize dose.

Super Noise Reduction Filter (SNRF)
Super Noise Reduction Filter (SNRF) improves image quality by reducing noise without introducing image lag.


Please accept preferences-cookies to watch this video.

AIP + SNRF brings Fluoro image quality to a new level

Please accept preferences-cookies to watch this video.

Dynamic Trace – get the overview in one go
Real time visualization of vessels over bones and anatomic landmarks with up to 60% lower dose than standard DSA technique.

Advanced Infinix-i dose reduction technologies

Please accept preferences-cookies to watch this video.

DoseRite – Better protection for patients and clinicians

The use of X-rays is a necessary evil during interventional procedures. That’s why reducing radiation exposure to patients and staff is a prime design concept for all Infinix-i systems. Here are a few of the methods operators can apply to control radiation dose.
DoseRite

Virtual Collimation

Virtual Collimation: After fluoroscopy, virtual collimation software simulates collimator positions so operators can adjust collimation with no additional fluoroscopy.

Grid Pulse Fluoro

Grid Pulse Fluoro: More efficient X-ray pulses to reduce leading and trailing-edge dose. Includes frame rate selection for Fluoro and Record between 1-30 frames per second (FPS).


Dose Control

Dose Control: Radiation dose levels can be monitored in real time through digital display in the examination room.

SNRF

Super Noise Reduction Filter (SNRF): Improves image quality by reducing noise without introducing image lag, enabling the user to work with lower dose at the same image quality level. 


Fluoro Store

Fluoro Store: Provides prospective and retrospective image capture. The ability to instantly replay and review reduces the need to repeat exposures, reducing dose.

Live Zoom

Live Zoom represents an additional function to obtain the same anatomical magnification without increasing dose.


Spot Fluoroscopy

Spot Fluoroscopy enables interventional efficiency while enhancing dose reduction capabilities. Clinicians can observe a region of anatomy using live fluoroscopy while viewing the Last Image Hold (LIH) surrounding area.

DTS

DTS – Dose Tracking System is a dose awareness tool that provides estimated dose information for the patient’s body surface in realtime.